📄 Source: InterconnectDiagnosticsLinkOpticalPower.php
<?php
/*
* Copyright 2014 Google Inc.
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not
* use this file except in compliance with the License. You may obtain a copy of
* the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
* WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
* License for the specific language governing permissions and limitations under
* the License.
*/
namespace Google\Service\Compute;
class InterconnectDiagnosticsLinkOpticalPower extends \Google\Model
{
/**
* The value has crossed above the high alarm threshold.
*/
public const STATE_HIGH_ALARM = 'HIGH_ALARM';
/**
* The value of the current optical power has crossed above the high warning
* threshold.
*/
public const STATE_HIGH_WARNING = 'HIGH_WARNING';
/**
* The value of the current optical power has crossed below the low alarm
* threshold.
*/
public const STATE_LOW_ALARM = 'LOW_ALARM';
/**
* The value of the current optical power has crossed below the low warning
* threshold.
*/
public const STATE_LOW_WARNING = 'LOW_WARNING';
/**
* The value of the current optical power has not crossed a warning threshold.
*/
public const STATE_OK = 'OK';
/**
* The status of the current value when compared to the warning and alarm
* levels for the receiving or transmitting transceiver. Possible states
* include: - OK: The value has not crossed a warning threshold.
* - LOW_WARNING: The value has crossed below the low warning threshold.
* - HIGH_WARNING: The value has crossed above the high warning threshold.
* - LOW_ALARM: The value has crossed below the low alarm threshold. -
* HIGH_ALARM: The value has crossed above the high alarm threshold.
*
* @var string
*/
public $state;
/**
* Value of the current receiving or transmitting optical power, read in dBm.
* Take a known good optical value, give it a 10% margin and trigger warnings
* relative to that value. In general, a -7dBm warning and a -11dBm alarm are
* good optical value estimates for most links.
*
* @var float
*/
public $value;
/**
* The status of the current value when compared to the warning and alarm
* levels for the receiving or transmitting transceiver. Possible states
* include: - OK: The value has not crossed a warning threshold.
* - LOW_WARNING: The value has crossed below the low warning threshold.
* - HIGH_WARNING: The value has crossed above the high warning threshold.
* - LOW_ALARM: The value has crossed below the low alarm threshold. -
* HIGH_ALARM: The value has crossed above the high alarm threshold.
*
* Accepted values: HIGH_ALARM, HIGH_WARNING, LOW_ALARM, LOW_WARNING, OK
*
* @param self::STATE_* $state
*/
public function setState($state)
{
$this->state = $state;
}
/**
* @return self::STATE_*
*/
public function getState()
{
return $this->state;
}
/**
* Value of the current receiving or transmitting optical power, read in dBm.
* Take a known good optical value, give it a 10% margin and trigger warnings
* relative to that value. In general, a -7dBm warning and a -11dBm alarm are
* good optical value estimates for most links.
*
* @param float $value
*/
public function setValue($value)
{
$this->value = $value;
}
/**
* @return float
*/
public function getValue()
{
return $this->value;
}
}
// Adding a class alias for backwards compatibility with the previous class name.
class_alias(InterconnectDiagnosticsLinkOpticalPower::class, 'Google_Service_Compute_InterconnectDiagnosticsLinkOpticalPower');
← Back